CAN FD Controller IP

Filter
Filter

Login required.

Sign in

Compare 24 IP from 14 vendors (1 - 10)
  • DO-254 CAN FD Controller
    • Design Assurance Level A according to RTCA DO-254/ED-80 (April, 2000)
    • Fully compliant to ISO 11898-1:2015
    • Supports both Classical and Flexible Data Rate frame formats
    • Tested as specified in the ISO 16845-1:2016
    Block Diagram -- DO-254 CAN FD Controller
  • CAN FD controller
    • Compatible with both CAN 2.0B and CAN-FD
    • Fully compliant with ISO 11898-1:2015
    Block Diagram -- CAN FD controller
  • Configurable CAN Bus Controller IP with Flexible Data-Rate
    • Designed in accordance to ISO 11898-1:2015
    • Supports CAN 2.0B and CAN FD frames
    • Support up to 64 bytes data frames
    • Flexible data-rates supported
  • CAN FD Bus Controller IP
    • CAN FD IP Core Implements the CAN 2.0A and CAN 2.0B protocol. ISO 11898-1 compliant
    • Supports ISO CAN-FD – ISO 11898-1:2015 DIS compliant
    • Listen-Only Mode enables CAN bus traffic analysis and automatic bit-rate detection
    • Loopback mode for self-testing
  • CAN FD Bus Controller
    • ASIL-C, ISO26262 Certified, Automotive Grade
    • Implements the CAN 2.0A and CAN 2.0B protocols
    • Supports ISO CAN-FD-ISO 11898-1:2015 DIS protocols
    • Non-ISO BOSCH CAN-FD Protocol
    Block Diagram -- CAN FD Bus Controller
  • CAN FD Light Bus Controller
    • CAN Specifications Support
    • No broadcast, no error frames, no advertising errors, simple, robust design
    • 11-bit identifier restriction for CAN-FD
  • Protocol controller IP for CAN / CAN FD
    • Support of Classical CAN and CAN FD according to ISO 11898-1:2015
    • Up to 64-byte payload for faster transmission of large data fields
    • Support of CAN FD Light:
    • standardization is ongoing by the by CiA (CAN in Automation).
    Block Diagram -- Protocol controller IP for CAN / CAN FD
  • Configurable CAN Bus Controller with Flexible Data-Rate
    • Designed in accordance with ISO 11898-1:2015 specification
    • Supports CAN and CAN FD frames
    • Supports up to 64 bytes of data frame
  • Protocol controller IP for Classical CAN / CAN FD / CAN XL
    • Net data rates up to 10Mbit/s
    • Large data fields with up to 2048 byte enable the use of higher layer
  • CAN 2.0 & CAN FD Bus Controller IP
    • Conforms to Bosch CAN 2.0B Active
    • 8/16/32-bit CPU slave interface with little or big endianess
    • Simple interface allows easy connection to CPU
    • Data rate up to 1 Mbps
    Block Diagram -- CAN 2.0 & CAN FD Bus Controller IP
×
Semiconductor IP