The need to address power during manufacturing test
By Anis Uzzaman, Patrick Gallagher, and Edward Malloy, Cadence Design Systems, Inc.
edadesignline.com (October 06, 2008)
Driven by the expansion of wireless and power-efficient devices and by the marketing requirement to deliver 'green' electronic systems, designers are increasingly employing low power design techniques to manage the growing challenge of functional power dissipation. Until recently, the idea of managing power during manufacturing test has been a secondary concern. But with shrinking geometries and lower voltage thresholds comes an increasing awareness that excessive power consumption during test can have an impact on digital IC reliability, leading to power-driven failures, infant mortality, and false failures at final test. The emergence of these phenomena calls for adoption of specific power management and low power design techniques for manufacturing test.
Power Consumption during Functional Mode vs. Test Mode
Several studies show that test mode power consumption in deep submicron devices can be several times higher than power consumption at functional modes. While typical test mode power consumption limits are usually around 2X functional power, in fact power consumption can be much higher, for a variety of reasons.
For instance, simultaneous testing of multiple modules is sometimes implemented to reduce tester costs -- even though in functional operation, it may be impossible to operate more than a few modules at a time. Switching within logic circuits during scan shift, and high switching rates during scan shift/capture, also produces higher power consumption during test. Similarly, fast at-speed capture pulses in transition test patterns can cause unwanted peak power spikes, leading to IR-drop issues. Finally, increasing the frequency of scan shift cycle to reduce test time can also cause unduly high power consumption at the tester.
Other departures from functional power consumption levels result from field test requirements for worst-case functional power; burn-in testing; and high-voltage testing of devices, all of which result in elevated voltages and temperatures, potentially creating negative impacts on both the test outcome and the device's low power circuitry.
edadesignline.com (October 06, 2008)
Driven by the expansion of wireless and power-efficient devices and by the marketing requirement to deliver 'green' electronic systems, designers are increasingly employing low power design techniques to manage the growing challenge of functional power dissipation. Until recently, the idea of managing power during manufacturing test has been a secondary concern. But with shrinking geometries and lower voltage thresholds comes an increasing awareness that excessive power consumption during test can have an impact on digital IC reliability, leading to power-driven failures, infant mortality, and false failures at final test. The emergence of these phenomena calls for adoption of specific power management and low power design techniques for manufacturing test.
Power Consumption during Functional Mode vs. Test Mode
Several studies show that test mode power consumption in deep submicron devices can be several times higher than power consumption at functional modes. While typical test mode power consumption limits are usually around 2X functional power, in fact power consumption can be much higher, for a variety of reasons.
For instance, simultaneous testing of multiple modules is sometimes implemented to reduce tester costs -- even though in functional operation, it may be impossible to operate more than a few modules at a time. Switching within logic circuits during scan shift, and high switching rates during scan shift/capture, also produces higher power consumption during test. Similarly, fast at-speed capture pulses in transition test patterns can cause unwanted peak power spikes, leading to IR-drop issues. Finally, increasing the frequency of scan shift cycle to reduce test time can also cause unduly high power consumption at the tester.
Other departures from functional power consumption levels result from field test requirements for worst-case functional power; burn-in testing; and high-voltage testing of devices, all of which result in elevated voltages and temperatures, potentially creating negative impacts on both the test outcome and the device's low power circuitry.
To read the full article, click here
Related Semiconductor IP
- nQrux® Root of Trust IP
- AXI to UCIe Bridge IP
- UCIe 2.x Controller IP
- SWI3S (SoundWire I3S Interface) Peripheral Controller Core IP
- OpenTitan-based RISC-V Secure Element
Related Articles
- Design for Low-Power Manufacturing Test
- Power of UVM's Command Line Argument Usage in Verification Test benches
- Test engineers must join ASIC flow early
- SoC Test and Verification -> How to verify ADSL chips
Latest Articles
- A Secure dToF LiDAR SoC with Dual-Domain Fingerprinting and Event-Driven AFE Circuit Achieving Sensor-Level Attack Resilience
- ZTA-Q: an Open-source RISC-V Platform for Accurate Quantized CNN Inference
- Automated Pre-Silicon Verification of High-Speed DDR5 and LPDDR5/6 Memory Controllers: Closed-Loop Timing, Mode Register, and PHY Synchronization in UVM
- U-Sonic: An Open-Source 8-Channel Ultrasound Transmit IP in a 130 nm RISC-V SoC
- S-ALSA: Co-Design of Adiabatic Logic-based Sensing and Balanced Bit-Cells for Secure and Energy-Efficient MRAM